Regqueryvalueex is unsuccessful for software microsoft sms task sequence

When you deploy operating systems by using pxe, you can configure whether the deployment is required or available. Reboot 2 and regqueryvalueexw is unsuccessful for software \ microsoft \ sms \ task sequence select all open in new window. Ts doesnt start with a regopenkeyexw is unsuccessful for. When i run it as part of the task sequence, it fails. Then we read that you have to import the drivers as driver packages dont work as before. The one of the option is to remove mp role and add it back. I am opening a handle to hklm\ software \ microsoft \eventsyst. After some unnecessary and failed troubleshooting attempts, checking the bios for the failing systems prompted to something similar and rather unusual. We removed mp however the remote sccm mp deinstall was not successful, it got failed.

Task sequence failed with the error code 0x80070002. Feb 08, 2012 this problem occurs because of a pxe cache limitation of 1 hour if system center configuration manager 2007 service pack 1 sp1 has been upgraded to sp2 after the hotfix that is described in kb 9691 has been applied in a configuration manager 2007 sp1 environment. Ive created a build and capture sccm osd task sequence to deploy win 7 enterprise 32bit which runs fine until the first reboot. Task sequence fails while applying operating system with.

Fixes an issue in which a custom software center logo that has a file name that. Osd on hp proliant server deploying operating systems. Es lost fruhere versionen mit dem namen systems management server sms ab. Start to cleanup task sequence policy tsmanager 11212019 11. Describes the issues fixed in the update rollup for microsoft system center configuration manager current branch, version 1702. Pending sccm remote distribution point community forums. This seems to be anywhere from between 5 minutes to 2 days. After this point the machine boots to windows and i can log in. Your code is mixing tchar and char types, and using wide function calls. From the smsts log i get the regqueryvalueexw is unsuccessful for software \ microsoft \ sms \ task sequence, smstsendprogram entry, but dont know what to do to resolve.

Program rejected wrong platform at end of sccm osd for. Task sequence fails in configuration manager if software updates require multiple restarts. Then it downloaded the task sequence content to local disk, and prompt to remove the bootable media and restart the device. Configmgr use download package content task sequence step. It is difficult to troubleshoot the machines where the task sequence os deployment failed remotely. Regqueryvalueexw is unsuccessful for software \ microsoft \ sms \ task sequence, smstsendprogram. Evening all, we have about 20 out of about 500 machines that have the same issue where they will build. I noticed that this key contained the site code of the old site which was usa. It works perfectly fine however, it reports back to sccm that the bios update failed. Preboot execution environment pxe boot in system center 2012 configuration manager configmgr 2012 or configmgr 2012 r2 and later versions enables administrators to easily access the windows preinstallation environment winpe across the network via pxe. Feb 20, 2017 im having random issues with my deployments for windows 10.

Have a question regarding driver packages in sccm 2012. Clients do not automatically wake using the wake on lan feature when deadlines for mandatory software distribution, software update, or task sequence deployments are reached. Once you are there find the sccm thread you wanted to restart. Log file reference configuration manager microsoft docs. Now when trying to deploy any image on any hardware, 2008 or 2012, dell or hp servers. The windows folder location is stored in this variable. And here is the task sequence condition example to check registry.

Advertised sccm os deployment task sequence does not pxe boot. Strange error from commandline task in mdt, diskpart, keep. X1 carbon model 20fc fails after applying os through mdt process. During a sccm osd task sequence, the sccm client is placed in. I see the first white configmgr screen but after a delay the machine just reboots without any errors, messages, etc. Let the compiler add it based on your project settings. Win 10 18031809 inplace upgrade on e7470 always fails. At the very end there is an error regqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogram which may. Asking for help, clarification, or responding to other answers. Then i made a new task sequence sysprep and capture kust the default. I guess that you have a 32 bit process and a 64 bit machine. An error occurred while retrieving policy for this computer. You shouldnt put a manual restart step after setup windows and config mgr, it will restart automatically anyway.

The hta script is to create a computer account in sccm and add it to our osd collection, and so this computer can receive our os task sequence advertisement. Unable to read certain registry keys in c stack overflow. May, 2016 regopenkeyexw is unsuccessful for the software microsoft sms task sequence. However, when deploying a parent task sequence, be aware that the criteria for showing the highimpact warning is not detected in software center when the child task sequence contains the highimpact steps. Weve come up with a good way of sending an email outlining task sequence completion status. Jul 01, 2015 regopenkeyexw failed for software \ microsoft \ sms \ task sequence gettsregvalue failed. Os deployment thread, certain machines fail to register in sccm correctly in technical. Windows 10 task sequence fails configuration manager 2012. Hello, i need to deploy a bios update for a specific model through sccm on encrypted computers.

Ive started to notice that after an osd completes, there is a folder c. I am attempting to play with some of the 16 and 32 bit registry functions, and im having trouble with using regqueryvalue not extended. Ive got an issue where im booting from standalone media. Im trying to setup additional software so that it installs a few things post install. The task sequence scans the computers hard drives for a previous operating system installation when windows pe starts. After the second reboot, the machine loads into a black screen and will sit in that state until i manually restart and fails back to windows 7, or if left alone will eventually fail and roll back on its own. Solved regqueryvalueexw giving error for windows registry. Ts fails at setup windows and configuration manager after.

Good day, when running the osd after selecting the ts that will be used, the checking dependencies step runs and then the pc reboots. Upgraded existing deployment server with new 20 release 2 and current windows 10 mdk. Configmgr 2012 standalone media machine boots into task. Windows 7 services sms task sequence agent tsmanager.

The log file has hundreds of the following errors, one right after another, failed to open software\microsoft\sms \mobile client\software distribution registry key. Try and use the win pe driver instead of the proper i tried that and then it didnt even make it to the network stage without failing so seems i need the driver. Sccm task sequence hangs on installing solutions experts. The machines mac and hostname are added to a collection, and then we pxe boot the machine, choose the appropriate task sequence win7 test 3 and then it installs windows and a bunch of applications. When this happens, registry redirection confounds matters. Task sequence manager execution terminated as system shutdown is in progress.

Hi, there are lots of different methods to query ad site name in a task sequence, one of them is querying the ad sitename value from registry. Do you just have a task that runs a batch file that does the diskpart clean for you before it tries to format and partition the drive. Required deployments use pxe without any user intervention. Hklm\ software \wow6432node\ microsoft \ sms \mobile client\ software distribution\state\paused and. Both boot images have been deployed to the distribution point and i can get the system to pick up a task sequence. We have an sccm 2007 server that deploys win7 x64 to our new pilot machines via pxe boot. However, after it formats the drive, the pxe multicast session is started then read more. I have received the new model of the x1 carbon in my environment and have started testing our imaging process.

You can help protect yourself from scammers by verifying that the contact is a microsoft agent or microsoft employee and that the phone number is an official microsoft global customer service number. Occasionally, i will get a white screen for the summary. When you deploy the task sequence to a collection and when you. If you are using a commandline task, you can specify. Hi, so, i am having some problems with the remote dp, i have deleted and recreated the site, even gone as far as deleting the vm and building a new server. Certain machines fail to register in sccm correctly edugeek. Fixes an issue in which dynamic media in configuration manager cannot get management point locations when the task sequence wizard runs in windows pe. Certain machines fail to register in sccm correctly. During refresh scenarios, install to original disk and partition. If a machine is left alone long enough and logged in i believe, then the task sequence will eventually complete. This key is located under hklm\ software \ microsoft \ sms \mobile client. Regopenkeyexw is unsuccessful for software \ microsoft \ sms \ task sequence 7102019 6. How to create an operating system deployment task sequence.

I rebooted and redeployed the task sequence, but same problem. Software center may show that updates are being installed and that some have. Typically you will copy the task logs to a share for inspection. Most the things in my searching say like verify network, access account. Depending on the environment the task sequence is running in, you can then take appropriate action. Deploy applications in task sequence configuration. Oct 16, 20 a very important clue is that the sms task sequence agent is still running. Windows system and applications information center. Sccm configmgr 2012 r2 mp deinstallation failed and client. You can configure your task sequence to retrieve this value from the environment and use it to specify the same windows. We currently have two imaging processes one is our standard, image delivery through usb flash drive talk about being in the stone age, right.

The application details pane in software center incorrectly shows a status of installing instead of an error condition. Task sequence fails in configuration manager if software. My problem is that the task sequence does not fully. Sccm an error occurred while retrieving policy for this computer 0x80004005. When oldvalue is few letters longer than newvalue, func. Failed to open software\microsoft\sms\mobile client question. Thanks for contributing an answer to stack overflow. Jul 12, 20 advertised sccm os deployment task sequence does not pxe boot on a new machine you may be having trouble deploying an operating system to a brand new machine even after you have advertised an os deployment task sequence to its correct mac address. I have sccm 2012 r2 sp1 and i was able to image machines using pxe boot to deploy the task sequences for imaging. This can be found in one of several locations depending on the progress of the build and the architecture of the os.

Mdt deployment white summary screen software deployment. Pending osd regqueryvalueexw is unsuccessful for software. I found that it was gprequestedsiteassigmentcode in the registry. Microsoft doesnt tell you what registry key holds the site code information. Sccm task sequence log file locations the first step to troubleshoot sccm osd task sequence issues to is check out the log file this is called smsts. The client should not get checked for rwh oplock type. We are finding that our task sequence stops at the setup windows and configuration manager step.

In sccm, create a status filter rule by going to site database site management primary site site settings status filter rules. At the very end there is an error regqueryvalueexw is unsuccessful for software \microsoft\sms\task sequence, smstsendprogram which. Imagine you are editing your masterpiece and you make a change to the task sequence and click apply. Ive captured my image, created the task sequence and pxe boot is working. How to restart sms executive threads like cloud user sync. Jul 21, 2017 a relatively new feature that is available with configmgr is the ability to download the content of a package during a task sequence. I have a vbscript which works abolultuly fine on my workstation. However i reloaded the boot image with the latest adk just fine. Regopenkeyexw is unsuccessful for software \ microsoft \ sms \ task sequence. This can result in os deployment task sequences running again. Ive borrowed a task sequence off another user in the company, and made some changes. Mar 04, 2016 it has a link to a microsoft technet article that says you need to make sure that the configmgr task sequence agent service needs to be configured to depend on the sms agent host, which i have done. A typical failure gets to about 82%ish in the working on updates, dont turn off your pc.

We would like to show you a description here but the site wont allow us. This video actually describes how to do reformating of a os disk only, but there is one option missing in the install operating system task in the mdt 6. New sccm instance and task sequence is bombing out. Regqueryvalueexw is unsuccessful for software \ microsoft \ sms \ task sequence, smstsendprogram gettsregvalue is unsuccessful. Querying registry for ad site name in a task sequence. Regqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogram osdsetuphook 520.

After updating to configuration manager current branch, version 1810, the sms agent host service ccmexec. The deployment partitions the drive, injects drivers, then fails on os image apply. A system center configuration manager 2007 sp2 task sequence. Regqueryvalueexw is unsuccessful for software \ microsoft \ sms \ tas k sequence, smstsendprogram gettsregvalue is unsuccessful. Try and use the win pe driver instead of the proper i tried that and then it didnt even make it to the network stage without failing so seems i. Sccm an error occurred while retrieving policy for this.

Sccm client site code discovery unsuccessful prajwal desai. The situation that brought it to my attention was that i was trying to run a powershell script as part of the sequence. It queries sccm to find out what domain a computer is in. The picture show, probably an older version of mdt. The create task sequence media operation may fail if the configuration manager version 1702 client is installed on the. A system center configuration manager 2007 sp2 task sequence may fail if the computer has multiple drives or partitions and usmt 4 with hardlinking is being used. Hello all, what i am trying to do is use sccms own osd task sequence windows pe to deploy an operating system that boots using vhd native boot. Task sequence failed with the error code 0x80070002 prajwal. Note that this is almost the last step in the task sequence, under windows 7, not windows pe. Tech support scams are an industrywide issue where scammers trick you into paying for unnecessary technical support services. From the smsts log i get the regqueryvalueexw is unsuccessful for software\ microsoft\sms\task sequence, smstsendprogram entry, but. The following sections list log files that are on the site server or that are related to specific site system roles.

Dec 11, 2017 after that, the parent task sequence can be deployed like any other task sequence. Aug 27, 2010 i had this problem today so thought id blog about it, as its so annoying. Sccm osd on uefi tablet thinkpad 10 problem 20161117, 17. Sccm 2012 osd error 0x80004005 microsoft community. Hi all, hopefully this is pretty straight forward, but this is my first foray into os deployment with sccm. From the smsts log i get the regqueryvalueexw is unsuccessful for software\microsoft\sms\task sequence, smstsendprogram entry, but. Finalize logging request ignored from process 3992 waiting for ccmexec service to be fully operational ccmexec service is up and fully operational. I created a task sequence to disable bitlocker, update bios silently and then reboot and reenable bitlocker. Hi, been a while since i had to do anything to my environment but last week i finally updated sccm 2012 sp1 to 1606.

Sccm osd task sequence problem resolved ars technica. If there are one or two computers which are in front of you,you can check press f8 and see what happens by looking at smsts. It was software\microsoft\smsso, just add software\microsoft\sms to. Learn how to keep in touch and stay productive with microsoft teams and microsoft 365, even when youre working remotely.

1294 1408 1077 705 1290 522 938 1447 963 593 992 844 1273 1421 733 453 1232 632 1084 464 884 902 72 1342 355 530 3 105 1083 884 1084 301 471 642 512 450 558 244